SOLONAX
Home / Products / Geogrids

Geogrids

Uniaxial, biaxial and triaxial reinforcement, 20–1 000 kN/m

SOLONAX GG

Polymer reinforcement for retaining structures, embankments over soft ground and pavement stabilisation. Uniaxial PET grids carry the long-term design load in reinforced soil walls; biaxial and triaxial PP grids confine granular layers so a thinner base course carries the same traffic.

Why it is specified

  • Junction efficiency ≥ 90 % — the junction, not the rib, governs stabilisation
  • Tensile stiffness reported at 2 % and 5 % strain, not ultimate strength alone
  • PVC-coated PET yarn: creep-limited strength verified to 120 years
  • Installation damage and durability factors published for common fill types
Range

Variants

CodeDescription
GG-UUniaxial PET, 55–1 000 kN/m — MSE walls, steep slopes, bridge abutments
GG-BBiaxial PP, 20–40 kN/m — subgrade stabilisation under granular fill
GG-TTriaxial PP — radial stiffness for unpaved haul roads and working platforms
GG-CGrid-geotextile composite — reinforcement and separation in one roll
Data

Technical specification

Uniaxial PET geogrid — GG-U series
PropertyTest methodMQC frequencyUnit5580110150200
Ultimate tensile strength (MD)EN ISO 103195 tkN/m5580110150200
Tensile strength at 2 % strainEN ISO 103195 tkN/m1826364965
Tensile strength at 5 % strainEN ISO 103195 tkN/m33486690120
Elongation at nominal strength, max.EN ISO 103195 t%1010101010
Junction efficiency, min.GRI-GG220 t%9090909090
Aperture size (MD × CD)per rollmm20 × 22020 × 22020 × 22020 × 22020 × 220
Roll dimensionsper rollm3.80 × 1003.80 × 1003.80 × 1003.80 × 503.80 × 50
Biaxial PP geogrid — GG-B series
PropertyTest methodMQC frequencyUnit20/2030/3040/40
Tensile strength MD / CDEN ISO 103195 tkN/m20 / 2030 / 3040 / 40
Tensile strength at 2 % strainEN ISO 103195 tkN/m7 / 710 / 1014 / 14
Aperture sizeper rollmm33 × 3339 × 3939 × 39
Roll dimensionsper rollm3.90 × 503.90 × 503.90 × 50

Indicative nominal / minimum average roll values. A project-specific technical data sheet, certificate of analysis and drop-in specification are issued with every order.

Send us the drawings.

A specification review before tender costs nothing and usually changes something.

Request a quote Resources